Why it matters: One of the most asked chapters. Know evaporation and condensation, latent heat, the kinds of humidity (absolute, specific, relative) and their differences, dew point, adiabatic lapse rates, stability and instability (absolute, conditional), and then fog, clouds, rainfall types, theories of raindrop formation and world rainfall on the sub-pages below.
1. Water vapour and evaporation ⭐
- Humidity = the amount of water vapour in the air at a given time and place.
- Water vapour is usually about 0–4% of the air by volume (average about 2%). About half of it lies below about 2 km.
- Water exists as solid (ice, snow, frost), liquid (water) and gas (vapour).
- Vapour controls precipitation, heat loss by radiation, surface temperature, latent heat, and the stability of air masses.
- Evaporation = change of liquid water into vapour. It increases with:
- dryness of the air (low relative humidity)
- temperature
- wind speed
- More evaporation happens over oceans than over land.
- Over land: most between 10°N and 10°S.
- Over oceans: most at 10°–20° latitude (trade-wind belts with dry air and steady winds).
- Condensation = change of vapour into liquid or solid; the opposite of evaporation.
2. Latent heat ⭐⭐
- Changing state needs heat without any change of temperature: this is latent (hidden) heat.
Change | Heat per gram |
Ice → water (melting) | About 80 cal (often given as 79) |
Water → vapour (evaporation) | About 540–600 cal (about 600 at 0°C, 540 at 100°C) |
- The heat used in evaporation is stored in the vapour and released on condensation as latent heat of condensation. This is a major source of energy for storms and cyclones.
- Evidence of cooling by evaporation: a fan cools a sweating body; spirit evaporating on the palm feels cold.
3. Humidity ⭐⭐⭐
Humidity capacity
- The maximum vapour a given volume of air can hold at a given temperature. It rises with temperature, and faster at higher temperatures.
- Measured in grains per cubic foot or grams per cubic metre.
- Air holding its full capacity is saturated.
Temperature (°F) | Capacity (grains/ft³) | Increase per 10°F |
30 | 1.9 | — |
40 | 2.9 | 1.0 |
50 | 4.1 | 1.2 |
60 | 5.7 | 1.6 |
70 | 8.0 | 2.3 |
80 | 10.9 | 2.9 |
90 | 14.7 | 3.8 |
100 | 19.7 | 5.0 |
Measures of humidity
Measure | Definition | Key points |
Absolute humidity | Weight of vapour per unit volume of air (g/m³ or grains/ft³) | Does not change with temperature alone, but changes when air expands or contracts (rising or sinking). Decreases from the equator to the poles and from oceans to continents |
Specific humidity | Weight of vapour (g) per kg of air | Not affected by expansion or contraction, so it is the best measure of actual moisture. Proportional to vapour pressure. About 0.2 g/kg in cold Arctic winter air, up to 18 g/kg in warm, moist equatorial air. Strahler called it "a geographer's yardstick" of water available for precipitation |
Relative humidity (RH) | (Actual vapour ÷ capacity at that temperature) × 100 | Expressed in %. Example: capacity 8 grains, actual 4 grains: RH 50% |
Relative humidity ⭐⭐⭐
- RH is inversely related to temperature: with the same moisture, warming lowers RH and cooling raises it.
Example: air holding a fixed 1.9 grains/ft³ of moisture at different temperatures:
Temperature (°F) | Capacity (grains/ft³) | RH (%) |
30 | 1.9 | 100 |
40 | 2.9 | 65.5 |
50 | 4.1 | 46.3 |
60 | 5.7 | 33.3 |
80 | 10.9 | 17.4 |
100 | 19.7 | 9.6 |
- RH changes in two ways: (i) more evaporation adds moisture; (ii) cooling lowers the capacity. Example: air at 50°F with 1.9 grains has RH 46%; cooled to 40°F by rising, RH becomes 65.5%.
- Importance:
- It shows the chance of precipitation; high RH means wet weather is likely.
- It controls evaporation.
- It affects human comfort: hot and humid equatorial air and very dry desert air are both uncomfortable.
- It affects buildings and equipment.
- Distribution:
- Highest near the equator; lowest in the sub-tropical highs (25°–35°); higher again towards the poles.
- The zones shift with the Sun.
- During the day RH is highest at dawn (coolest time) and lowest in the early afternoon (warmest time).
4. Condensation and dew point ⭐⭐
- Air becomes saturated (RH 100%) in two ways:
- More moisture is added at the same temperature.
- The air is cooled until its capacity equals its moisture.
- Dew point = the temperature at which air becomes saturated. Example: air at 60°F holding 4.1 grains (RH 72%) becomes saturated when cooled to 50°F, so its dew point is 50°F.
- Condensation needs slight further cooling and hygroscopic (condensation) nuclei: dust, salt, smoke.
- If the dew point is above freezing, condensation is liquid (dew, fog, cloud droplets, rain). If below freezing, it is solid (frost, ice crystals, snow).
- Rising air cools and may give clouds and rain. Sinking air warms and stays dry. Dry hot air needs much cooling to reach its dew point; humid air needs little.
5. Adiabatic change of temperature ⭐⭐⭐
- Normal (environmental) lapse rate: the fall of temperature with height in still air: 6.5°C per km (3.6°F per 1,000 ft). It varies from place to place and time to time.
- Adiabatic change: the temperature of a rising or sinking parcel of air changes without any heat being added or removed. Rising air expands and cools; sinking air is compressed and warms. Air rising from sea level to about 5.3 km (17,500 ft) doubles its volume.
Rate | Value | Applies to |
Dry adiabatic lapse rate (DALR) | 10°C per km (5.5°F per 1,000 ft); constant | Unsaturated air, rising or sinking |
Wet (moist, saturated or retarded) adiabatic lapse rate (SALR) | About 5–6°C per km (about 3°F per 1,000 ft); varies, slower in warm air | Saturated air rising above the condensation level, where released latent heat slows the cooling |
6. Stability and instability ⭐⭐⭐
- Stable air resists vertical movement; a lifted parcel sinks back. Unstable air keeps rising on its own, forming clouds and rain.
- It depends on comparing the environmental lapse rate (ELR) with the adiabatic rates.
Condition | Rule | What happens |
Absolute stability | ELR less than the wet adiabatic rate | A rising parcel is always colder than its surroundings and sinks back. Example: ground air 40°C, DALR 10, ELR 6.5: at 1 km the parcel is 30°C but the air around is 33.5°C, so the parcel sinks |
Absolute instability | ELR greater than DALR (10°C/km) | A rising parcel is always warmer and keeps rising. Example: ELR 11°C/km: at 1 km the parcel is 30°C and the surroundings 29°C, so the parcel rises |
Conditional instability ⭐ | ELR between the wet and dry adiabatic rates (e.g. 6.5°C/km) | Stable while the air is unsaturated. If it is forced up past condensation, it then cools at only about 5°C/km, becomes warmer than its surroundings and rises on its own. This is common in the tropics and gives thunderstorms |
Neutral equilibrium | Parcel temperature equals its surroundings | Neither rises nor sinks |
Mechanical (auto-convective) instability | ELR extremely steep (above about 34°C/km) | Upper air becomes denser than the air below and overturns; linked with tornadoes |